Skip to main contentEngineering Courses, Mentoring & Jobs | EveryEng
Inductors in Series and Parallel: Formulas, Calculation, and Applications banner

Inductors in Series and Parallel: Formulas, Calculation, and Applications

Formulas, Calculations, and Applications of Series and Parallel Inductors

Written byLearnEng Team Updated October 17, 2026 English
Technical ArticleReading Content
Inductors in Series and Parallel: Formulas, Calculation, and Applications banner
Views
165
  • Enhance Knowledge
  • Knowledge Sharing
  • Resource Networking

Free to join — save articles and keep learning.

LearnEng Team
LearnEng Team

Who is this article actually for?

Perfect for

  • You work in Electronics & Instrumentation
  • You're a Electrical Engineering / Electronics & Telecommunication professional
  • You have 3+ years of hands-on experience in this field

Before you enrol

  • Advanced level — assumes working knowledge of Electrical Engineering
New to Electrical Engineering? Browse beginner courses →

Article details

Introduction

Inductors are important electrical components used in power supplies, filters, transformers, motors, and electronic circuits. They store energy in a magnetic field when electric current flows through them. Depending on circuit requirements, inductors can be connected in series or parallel to achieve a desired inductance value.

Understanding inductors in series and parallel helps engineers calculate total inductance, analyze circuit behavior, and design efficient electrical and electronic systems.

What Is Inductance?

Inductance is the ability of a component to oppose changes in electric current by producing an induced voltage. It is represented by the symbol L and measured in henries (H).

The inductance of a coil depends on factors such as the number of turns, core material, coil dimensions, and magnetic properties of the surrounding environment.

Inductors are commonly used to reduce current fluctuations, filter electrical signals, store energy in switching circuits, and suppress electromagnetic interference.

Inductors Connected in Series

A series connection occurs when two or more inductors are connected one after another, creating a single path for current flow. The same current passes through every inductor in the circuit.

For ideal inductors without magnetic coupling, the total inductance is equal to the sum of their individual inductances.

Formula for Inductors in Series

The total inductance of inductors connected in series is calculated using the following formula:

Ltotal = L1 + L2 + L3 + ... + Ln

Where:

  • Ltotal = Total inductance

  • L1, L2, L3 = Individual inductance values

  • n = Number of inductors connected in series

Example of Series Inductance

Consider three inductors connected in series with the following values:

L1 = 2 H, L2 = 3 H, and L3 = 5 H.

Using the formula:

Ltotal = 2 + 3 + 5

Ltotal = 10 H

Therefore, the total inductance is 10 henries.

Applications of Series Inductors

Series-connected inductors are used in power supply circuits, electrical filters, current-limiting circuits, and noise suppression systems. They can increase the total inductance to achieve the required circuit performance.

Inductors Connected in Parallel

A parallel connection occurs when the terminals of multiple inductors are connected across the same two electrical nodes. Each inductor experiences the same voltage, while the total current divides between the available branches.

For ideal, uncoupled inductors, the reciprocal of the total inductance equals the sum of the reciprocals of the individual inductances.

Formula for Inductors in Parallel

The total inductance is calculated using the following formula:

1/Ltotal = 1/L1 + 1/L2 + 1/L3 + ... + 1/Ln

For two inductors connected in parallel, the formula can be simplified to:

Ltotal = (L1 × L2) / (L1 + L2)

Example of Parallel Inductance

Consider two inductors connected in parallel:

L1 = 6 H and L2 = 3 H.

Using the formula:

Ltotal = (6 × 3) / (6 + 3)

Ltotal = 18 / 9

Ltotal = 2 H

Therefore, the equivalent inductance is 2 henries.

Applications of Parallel Inductors

Parallel inductors are used in power converters, electronic filters, switching power supplies, and circuits requiring lower equivalent inductance. They can also help distribute current between branches when the components and circuit conditions are appropriately designed.

Difference Between Series and Parallel Inductors

The main difference between series and parallel connections is how the inductance values combine.

In a series connection, the total inductance increases as additional ideal, uncoupled inductors are added. In a parallel connection, the equivalent inductance is lower than the smallest individual inductance.

Series circuits carry the same current through every inductor, whereas parallel circuits maintain the same voltage across each branch.

These differences help engineers choose a suitable configuration based on the required inductance, current, voltage, and operating conditions.

Magnetic Coupling Between Inductors

The basic series and parallel formulas assume that the inductors do not have significant mutual magnetic coupling. When two coils are placed close to each other, the magnetic field produced by one coil can affect the other. This phenomenon is called mutual inductance.

For two magnetically coupled inductors connected in series, the equivalent inductance depends on whether their magnetic fluxes reinforce or oppose each other.

The formulas are:

Series aiding: Ltotal = L1 + L2 + 2M

Series opposing: Ltotal = L1 + L2 − 2M

Where M represents mutual inductance, measured in henries.

For ideal coupled coils connected in parallel, the equivalent inductance also depends on the mutual inductance and the relative winding polarity. Therefore, the simple parallel formula should not be applied without considering coupling when mutual inductance is significant.

Practical Considerations When Connecting Inductors

Engineers should consider several factors when designing circuits with series or parallel inductors.

  • Inductance tolerance: Actual inductance may differ from the rated value because of manufacturing tolerances.

  • Current rating: The current must remain within the inductor's rated limits to prevent overheating or magnetic saturation.

  • Winding resistance: Resistance causes power losses and affects practical circuit performance.

  • Magnetic coupling: Closely positioned inductors may influence each other's inductance.

  • Operating frequency: Inductor impedance changes with frequency, affecting the behavior of AC circuits.

  • Core saturation: Excessive current can reduce inductance in components with magnetic cores.

Considering these factors improves circuit reliability and helps prevent unwanted electrical losses.

Go deeper with a full course

Courses on the tools and skills this article covers.

Opportunities that await you!

Career opportunities

Free to read

Join EveryEng to save articles and keep learning

Why people choose EveryEng

Industry-aligned articles, expert knowledge, hands-on learning, and career-relevant topics — all in a flexible and supportive environment.

Put no limit on your engineering passion.

We would love to hear from you.

Engineers collaborating around a laptop