Plain Cement Concrete (PCC) is strong under compression but very weak in tension. Steel reinforcement (rebar, mesh, or fibers) absorbs tensile, shear, and bending stresses.

  • Language

    English

  • Type Of Article

    Technical Article

  • Content

    Reading Content

Plain Cement Concrete (PCC) is strong under compression but very weak in tension. Steel reinforcement (rebar, mesh, or fibers) absorbs tensile, shear, and bending stresses. banner

Free to join — save articles and keep learning.

9 views
LearnEng Team
LearnEng Team
  • Enhance Knowledge
  • Knowledge Sharing
  • Resource Networking

Article details

Plain cement concrete (PCC) resists crushing well but cracks easily when pulled or bent. Its tensile strength is only about 8 to 12 percent of its compressive strength. Steel reinforcement (rebar, welded mesh, or fibers) is strong in tension, so it is placed where tension develops. The combination, reinforced cement concrete (RCC), lets concrete do the compression work and steel do the tension work, producing a material that can form beams, slabs, and columns.

Why Plain Concrete Is Weak in Tension

  • Concrete is a brittle, stone-like material made of aggregate bound by hardened cement paste

  • Microcracks exist inside it even before loading, at the aggregate-paste interface

  • Under compression, these microcracks stay closed or grow slowly, so the material carries high loads

  • Under tension, the microcracks open and join almost immediately, causing sudden brittle failure

  • Shrinkage and temperature changes also create tensile stress, so even unloaded concrete can crack

Property

Typical value (M25 concrete)

Compressive strength

25 N/mm²

Tensile strength (direct)

About 2 to 3 N/mm²

Flexural strength (IS 456)

0.7 √fck, about 3.5 N/mm²

Failure mode in tension

Sudden, brittle

What Happens in a Beam

When a simply supported beam carries load, it bends:

  • Top fibers are squeezed (compression)

  • Bottom fibers are stretched (tension)

  • Near the supports, shear forces create diagonal tension cracks

  • The neutral axis lies between, with no bending stress

A plain concrete beam cracks at the bottom at a small load and fails suddenly. Adding steel at the bottom face carries the tension after the concrete cracks, so the beam keeps carrying load and gives visible warning (wide cracks and deflection) before failure.

What Steel Does

Stress

How steel resists it

Tension

Main longitudinal bars carry the pull in beams, slabs, footings, and ties

Bending

Bars placed on the tension side of the section (bottom in sagging, top over supports)

Shear

Stirrups and bent-up bars cross diagonal cracks and hold the section together

Torsion

Closed stirrups and longitudinal bars around the perimeter

Temperature and shrinkage

Distribution steel and mesh control crack width

Compression

Steel in columns adds capacity and resists accidental bending

Confinement

Ties and spirals keep column concrete from bursting outward and add ductility

Why Steel and Concrete Work Together

Three natural compatibilities make RCC possible:

  1. Bond: hardened cement paste grips the bar surface, and ribbed (deformed) bars improve the grip, so the two strain together

  2. Similar thermal expansion: both expand about 10 to 12 × 10⁻⁶ per °C, so temperature changes do not break the bond

  3. Corrosion protection: the alkaline concrete (pH about 12.5 to 13) forms a passive film on the steel, protecting it as long as cover is adequate and concrete is dense

Forms of Reinforcement

Type

Description

Typical use

Rebar (TMT, Fe415, Fe500, Fe550)

Ribbed bars, 6 to 40 mm and above

Beams, columns, slabs, footings, walls

Welded wire mesh

Factory-welded grid of wires

Slabs on grade, pavements, precast panels

Steel fibers

Short discrete fibers mixed into concrete

Industrial floors, tunnel linings, shotcrete

Synthetic fibers

Polypropylene or similar

Plastic shrinkage crack control

Prestressing strand or wire

Tensioned high-strength steel

Long-span beams, bridges, slabs

Fiber-reinforced polymer (FRP) bars

Non-corroding bars

Marine and chemically aggressive environments

Stainless or galvanized bars

Corrosion-resistant steel

Splash zones, decks, coastal structures

Fibers vs bars: fibers control cracking and improve toughness and impact resistance, but they do not normally replace main bars in structural members carrying large bending loads, unless designed and tested for it.

Where Each Material Is Placed

Element

Reinforcement location

Simply supported beam

Main bars at bottom, stirrups along length, hanger bars at top

Continuous beam

Bottom steel at midspan, top steel over supports

Cantilever

Main bars at the top (tension face)

One-way slab

Main bars in the short span at bottom, distribution bars across

Two-way slab

Bars in both directions

Column

Vertical bars with lateral ties or spirals

Footing

Bottom mesh in both directions

Retaining wall

On the tension (soil) face of the stem, and at heel or toe bottom or top as analysis shows

The rule is simple: find where the member tends to stretch, and put steel there.

How a Reinforced Section Behaves

  1. Uncracked stage: both materials share stress, and the section behaves almost like plain concrete

  2. Cracked stage: tension cracks form in concrete at the bottom, and steel takes over the entire tension

  3. Yielding stage: steel yields (in an under-reinforced section), cracks widen, deflection grows visibly

  4. Failure: concrete crushes at the top after large deformation

Under-reinforced design (steel yields first) is the aim, because the beam warns before failing. Over-reinforced sections fail by sudden concrete crushing and are avoided by codes.

Basic Design Idea (Limit State)

For a rectangular beam section in bending:

  • Compression is carried by a concrete block at the top, with design stress about 0.446 fck in IS 456

  • Tension is carried by steel, with design stress 0.87 fy at yield

  • Equilibrium of forces: 0.36 fck b xu = 0.87 fy Ast

  • Moment capacity: Mu = 0.87 fy Ast (d − 0.42 xu)

where b is width, d effective depth, xu depth of neutral axis, and Ast area of tension steel. Codes also set minimum steel (for example 0.85 bd/fy for beams in IS 456) to avoid sudden failure at first cracking, and maximum steel to keep the section under-reinforced.

Minimum Cover and Detailing

Steel only works if it stays bonded and protected:

  • Cover protects against corrosion and fire (commonly 20 to 50 mm for ordinary buildings, more in severe exposure)

  • Spacing between bars allows concrete to flow and compact around them

  • Development length and laps let bars transfer force into concrete without slipping

  • Hooks and bends anchor bars at the ends

  • Stirrup spacing is closer near supports where shear is highest

Role of PCC in Construction

PCC is still widely used where tension is not significant:

Use

Purpose

Blinding layer under footings (75 to 100 mm)

Clean, level surface, protects steel from soil

Mass foundations and fillings

Bulk compression load transfer

Floor bases and sub-floors

Support finishes in non-structural conditions

Pavement bases and kerbs

Low-stress, bulk applications

Gravity retaining walls and dams (mass concrete)

Stability from self-weight

Leveling and haunching

Pipe bedding and encasement

Comparison

Feature

PCC

RCC

Compression

Good

Good

Tension and bending

Very poor

Good

Shear

Poor

Good with stirrups

Failure

Sudden, brittle

Ductile, gives warning

Cracking

Opens freely

Controlled by steel

Use

Mass, non-structural, bases

Beams, slabs, columns, structures

Cost per m³

Lower

Higher (steel and labor)

Durability concerns

Low (no steel to corrode)

Corrosion of steel if cover or quality is poor

Common Mistakes

  • Placing steel on the wrong face (for example, cantilever bars at the bottom)

  • Displaced bars from poor cover blocks, losing effective depth

  • Insufficient cover, leading to corrosion and spalling

  • Inadequate laps and anchorage

  • Congested steel causing honeycombing

  • Using PCC where tension is expected, such as long unreinforced slabs

  • Omitting shrinkage reinforcement in slabs

  • Dirty or rusted bars with poor bond

  • Cutting or bending stirrups on site without approval

Conclusion

Reinforced concrete succeeds because each material covers the other’s weakness: concrete is cheap, durable, and strong in compression, while steel supplies the tensile strength concrete lacks. The designer’s job is to understand where a member will be squeezed and where it will be stretched, then place steel in the stretched zones with enough cover, anchorage, and spacing for the two to act together. Values quoted here are typical, so always follow the current code and the structural engineer’s drawings for actual work.