Skip to main contentEngineering Courses, Mentoring & Jobs | EveryEng
Synchronous Speed of an Electric Motor: Formula, Calculation, and Applications banner

Synchronous Speed of an Electric Motor: Formula, Calculation, and Applications

Synchronous Speed Formula, Calculation, Factors, and Applications in AC Motors

Written byLearnEng Team Updated October 20, 2026 English
Technical ArticleReading Content
Synchronous Speed of an Electric Motor: Formula, Calculation, and Applications banner
Views
16
  • Enhance Knowledge
  • Knowledge Sharing
  • Resource Networking

Free to join — save articles and keep learning.

LearnEng Team
LearnEng Team

Who is this article actually for?

Perfect for

  • You work in Industrial Automation or Manufacturing & Industrial
  • You're a Electrical Engineering professional
  • You have some foundational knowledge in the subject

Before you enrol

  • Intermediate level — assumes the fundamentals of Electrical Engineering
New to Electrical Engineering? Browse beginner courses →

Article details

Introduction

Electric motors are essential components in industrial machinery, pumps, compressors, fans, conveyors, and automation systems. Understanding motor speed is important for selecting the right motor, improving operational efficiency, and ensuring reliable equipment performance.

One of the most important concepts in electrical engineering is synchronous speed. It refers to the speed at which the rotating magnetic field produced by an alternating current (AC) supply moves inside an electric motor.

Synchronous speed is particularly important when studying induction motors and synchronous motors. It depends mainly on the supply frequency and the number of magnetic poles in the motor.

What Is Synchronous Speed?

Synchronous speed is the rotational speed of the magnetic field generated by the stator of an AC motor. It is measured in revolutions per minute (RPM).

When a three-phase AC supply is applied to the stator windings, it produces a rotating magnetic field. This field rotates at a specific speed determined by the electrical supply frequency and the motor's pole count.

In a synchronous motor, the rotor rotates at the same speed as this magnetic field under normal synchronized operation. In an induction motor, the rotor generally rotates at a slightly lower speed because a difference in speed is necessary to induce rotor current and produce torque.

Understanding synchronous speed helps engineers determine the operating characteristics and suitability of different motor types.

Synchronous Speed Formula

The synchronous speed of an AC motor can be calculated using the following formula:

Ns = (120 × f) / P

Where:

  • Ns = Synchronous speed in revolutions per minute (RPM)

  • f = Supply frequency in hertz (Hz)

  • P = Number of magnetic poles

The constant 120 comes from converting the electrical frequency into revolutions per minute while accounting for the number of poles.

This formula shows that synchronous speed increases with supply frequency and decreases as the number of poles increases.

How to Calculate Synchronous Speed

Calculating synchronous speed is straightforward when the supply frequency and motor pole count are known.

Example 1: Four-Pole Motor at 50 Hz

Consider a four-pole AC motor operating at a supply frequency of 50 Hz.

Given:

  • Supply frequency = 50 Hz

  • Number of poles = 4

Using the formula:

Ns = (120 × 50) / 4

Ns = 6000 / 4

Synchronous speed = 1500 RPM

Therefore, the rotating magnetic field completes 1,500 revolutions per minute.

Example 2: Six-Pole Motor at 50 Hz

For a six-pole motor operating at 50 Hz:

Ns = (120 × 50) / 6

Ns = 6000 / 6

Synchronous speed = 1000 RPM

This demonstrates that increasing the number of poles reduces synchronous speed when the supply frequency remains constant.

Example 3: Four-Pole Motor at 60 Hz

Consider a four-pole motor connected to a 60 Hz supply.

Ns = (120 × 60) / 4

Ns = 7200 / 4

Synchronous speed = 1800 RPM

The higher supply frequency produces a higher synchronous speed compared with a four-pole motor operating at 50 Hz.

Synchronous Speed Chart

The following table shows common synchronous speeds for different motor pole counts at 50 Hz and 60 Hz.

Number of Poles

Speed at 50 Hz

Speed at 60 Hz

2 poles

3000 RPM

3600 RPM

4 poles

1500 RPM

1800 RPM

6 poles

1000 RPM

1200 RPM

8 poles

750 RPM

900 RPM

10 poles

600 RPM

720 RPM

12 poles

500 RPM

600 RPM

These values represent the speed of the rotating magnetic field. The actual rotor speed of an induction motor is normally lower than the corresponding synchronous speed.

Factors Affecting Synchronous Speed

Two main factors determine the synchronous speed of an AC motor.

1. Supply Frequency

Supply frequency represents the number of electrical cycles per second. It directly affects the speed of the rotating magnetic field.

For example, increasing the supply frequency from 50 Hz to 60 Hz increases synchronous speed by 20% when the pole count remains unchanged.

Variable frequency drives (VFDs) use this principle to control the speed of suitable AC motors by adjusting the frequency supplied to the motor.

2. Number of Poles

The number of poles determines how the magnetic field is distributed around the stator. A motor with fewer poles has a higher synchronous speed, while a motor with more poles has a lower synchronous speed at the same frequency.

High-speed applications often use two-pole or four-pole motors, while lower-speed applications may use six-pole or eight-pole motors.

Selecting the appropriate pole count helps engineers match motor characteristics to the requirements of industrial equipment.

Synchronous Speed vs. Actual Motor Speed

Synchronous speed and actual rotor speed are related, but they are not always identical.

In a synchronous motor, the rotor locks into synchronism with the rotating magnetic field during normal operation. Its speed matches synchronous speed as long as it remains synchronized.

In an induction motor, the rotor must rotate more slowly than the magnetic field to maintain the relative motion needed to induce rotor current and generate torque. This difference is called slip.

The actual speed of an induction motor depends on its load, design, and operating conditions.

For example, a four-pole induction motor operating on a 50 Hz supply has a synchronous speed of 1500 RPM. Its actual full-load speed might be approximately 1450 RPM, depending on the motor design and rated load.

Understanding Motor Slip

Slip is the difference between synchronous speed and the actual rotor speed of an induction motor, expressed as a percentage of synchronous speed.

The slip formula is:

Slip (%) = [(Ns − Nr) / Ns] × 100

Where:

  • Ns = Synchronous speed in RPM

  • Nr = Actual rotor speed in RPM

For example, if the synchronous speed is 1500 RPM and the rotor speed is 1450 RPM:

Slip = [(1500 − 1450) / 1500] × 100

Slip = (50 / 1500) × 100

Slip = 3.33%

This value indicates that the rotor runs approximately 3.33% below synchronous speed. Slip is necessary for normal torque production in an induction motor.

Synchronous Motors vs. Induction Motors

Although both motor types use rotating magnetic fields, they differ in their operating principles.

A synchronous motor operates with its rotor synchronized to the stator's rotating magnetic field. Depending on its design, it may require a separate excitation system or permanent magnets. Synchronous motors are useful where precise, constant speed is important.

An induction motor produces rotor current through electromagnetic induction. Its rotor normally operates below synchronous speed, and the difference in speed allows torque to develop. Induction motors are widely used because of their robust construction, reliability, and relatively simple maintenance requirements.

The choice between these motors depends on factors such as speed requirements, starting conditions, efficiency, control needs, and application costs.

Applications of Synchronous Speed

Synchronous speed calculations are useful across several engineering and industrial applications.

  • Industrial pumps: Help engineers select suitable motor speeds for fluid transfer and circulation systems.

  • Fans and blowers: Support motor selection for ventilation and air-handling equipment.

  • Compressors: Help determine appropriate motor characteristics for industrial process systems.

  • Conveyors: Assist in selecting motors that meet material-handling speed requirements.

  • Power generation: Help explain the relationship between rotational speed, frequency, and the number of poles in synchronous generators.

  • Variable speed systems: Support the configuration of variable frequency drives for adjustable motor operation.

Accurate speed calculations can improve equipment selection, operational planning, and overall system performance.

Go deeper with a full course

Courses on the tools and skills this article covers.

Opportunities that await you!

Career opportunities

Free to read

Join EveryEng to save articles and keep learning

Why people choose EveryEng

Industry-aligned articles, expert knowledge, hands-on learning, and career-relevant topics — all in a flexible and supportive environment.

Put no limit on your engineering passion.

We would love to hear from you.

Engineers collaborating around a laptop