1. Understand the concept, performance measures and analysis of RCM

2. Get knowledge of the potential contribution of RCM to maintenance efficiency and performance

3. Know the Guidelines indicating how RCM interacts with • and supports other elements of maintenance strategy particularly condition monitoring and CBM

4. Understand Hints and tips for practical application of RCM • and associated technologies so as to achieve the best results.

A practical approach for developing an action • plan to utilize RCM in their own areas of responsibility, fitting KCM into the overall maintenance organization and strategy

Course details

This course presents the concepts and techniques of Reliability Centered Maintenance. It is specifically designed to meet the needs of managers, engineers, assistants and all technical personnel involved in maintenance. The course starts with maintenance background and maintenance evolution- history and modern thinking. It covers the role, impact, cost, and benefits of Reliability Centered Maintenance. It also covers the RCM techniques and methods such as the seven stages of RCM and FMECA. RCM implementation, organization, and sustaining benefits are also covered. By the end of the course, the attendees will be able to establish a RCM program suitable to their own facilities.

Course suitable for

Is this course for you?

Perfect for

  • You work in Automotive or Nuclear & Power
  • You're a Electrical Engineering / Instrumentation Engineering professional
  • You want to build skills in Electrical Maintenance, Kaizen
  • You prefer live, instructor-led training with Q&A

Before you enrol

  • No prior experience needed for this course
  • Live online sessions — join on the scheduled dates

Key topics covered

Day 1: Introduction and Background

The role and contribution of maintenance in modern business, How good maintenance enhances overall company performance, Bottom line benefits of getting maintenance right for your business

Day 2: Maintenance Evolution- History and Modern Thinking

Brief historical review of maintenance, Modern maintenance thinking and philosophy, Minimizing overall costs – capital (CAPEX) & operational (OPEX), Safety and environmental issues and drivers, Challenging traditional approaches to maintenance

Day 3: Understanding Reliability Centered Maintenance

RCM and overall maintenance strategy, Performance measures –Availability &OEE, Creating an optimized maintenance plan, Criticality & vulnerability analysis and assessment, Introduction to condition monitoring and links with RCM

Day 4: Reliability Centred Maintenance Techniques and Methods

Overall RCM program plan, Seven stages of RCM, Introduction to FMECA, RCM Analysis process, Benefits of RCM ON cost and performance

Day 5: RCM Implementation-Organization and Sustaining Benefits

Where are we now – benchmarking, Where can we improve - goal setting, Putting it into practice – implementation, Teamwork and organization Case studies

Training details

This is a live course that has a scheduled start date.

Opportunities that await you!

Career opportunities

Frequently asked questions

A: Governing principle: During the constant hazard period, MTBF is the inverse of the failure rate. Applied here, the given λ already reflects operating hours, so no duty factor or calendar conversion belongs in the calculation. Option D traps engineers who know to convert time bases but miss that λ is already normalized.

A: Governing principle: Failure modes must explain all observed symptoms, including when they appear. Here the temperature spike occurs during warm‑up and stabilizes later, consistent with clearance closing as metal expands. Option C fits hot-running failures but doesn’t match a startup‑only temperature rise.

A: Governing principle: Relief devices limit pressure; they don’t prevent loss of containment from material degradation. Corrosion reduces MAWP until normal operating pressure becomes unsafe, regardless of PSV capacity. Option A catches engineers who forget that liquid-full scenarios can still lift a PSV if set correctly.

A: Governing principle: Inspection frequency is set to reliably detect degradation before functional failure. Using half the P‑F interval provides margin without assuming a specific fouling rate shape. Option D reflects scheduling convenience creeping into what should be a reliability-based interval.