Skip to main contentEngineering Courses, Mentoring & Jobs | EveryEng
Storage tank design with special focus on Cryogenic fluids banner
Storage tank design with special focus on Cryogenic fluids banner
Live Online Class Basic

Storage tank design with special focus on Cryogenic fluids

4(6)
2373 views
Trainers Rating
4(6)
Course type
Instructor led live training
Duration
-
Start
Next month
Views
2373
  • 7-day money-back guarantee
  • Session recordings included
COMPLETED

Tell us and we’ll notify you when the next batch is scheduled.

Jyoti Swarup
Jyoti Swarup

Why enroll

API 650 tanks design concepts.

Storage Tank Accessories

Typical sizes, design pressures, horizontal and vertical Vacuum insulated tanks with inner/outer shell in SS/CS

Evaporation rates etc.

API 620 design Annex Q and R and API 625 tanks

Use of European codes for such tanks

Standard vacuum insulated tanks in the market

Large flat bottom storage tanks details.

Is this course for you?

Perfect for

  • You work in Oil & Gas Upstream or Pharmaceutical & Healthcare
  • You're a Chemical & Process / Mechanical Engineering professional
  • You prefer live, instructor-led training with Q&A

Before you enrol

  • No prior experience needed for this course
  • Live online sessions — join on the scheduled dates

Key topics covered

Types of above ground storage Tanks

Applicable API codes

Difference: API 620 and API 650 tanks

Tank Shell, Bottom Plate design

API 625 Storage concepts

Cryogenic Storage tanks types

Shop or site built?

Vacuum insulated tanks

Pressure Stretching

Flat Bottom tanks

Materials for tanks

Compression Rings

Shell connections

Insulations

Reference Codes and Standards

Training details

This is a live course that has a scheduled start date.

Opportunities that await you!

Career opportunities

Frequently asked questions

A: A: Surface area ~15,000 m² times 8 W/m² is ~120 kW. Divide by LNG latent heat and inventory, you land near 0.1%/day. That's the sanity check you do at 2 a.m. B: Vapor density doesn't rescue the energy balance; heat leak still rules. C: Roof losses matter, but not enough to double the rate at this scale. D: CFD refines it later; this call is about order-of-magnitude risk triage.

A: A: Full containment means exactly that — credible inner tank rupture with liquid retained. That's the safety logic. B: NFPA 59A distances don't replace containment philosophy. C: Structural-only thinking ignores why prestressing and crack control exist. D: Procedural overfill controls aren't accepted as a primary barrier in hazard analysis.

A: A: At cryogenic service, cold spring and vapor density matter; 0.15 barg vs 0.2 barg leaves no operating margin. B: Parallel PSVs are common when sized correctly and manifolded. C: Nozzle size depends on relieving case, not tank volume alone. D: MAWP vs design pressure mismatch often hides a real assumption gap.

A: A: This is the industry workhorse for large LNG tanks and behaves predictably at −162 °C. B: Carbon steel hits brittle transition well above LNG temperature. C: Duplex loses toughness and isn't qualified for this service. D: Aluminum works cryogenically, but dismissing it purely on seismic grounds mixes material and structural issues.

COMPLETED

$214

Coming in Next Month

What learners say about this course

Industry-aligned courses, expert training, hands-on learning, recognized certifications, and job opportunities-all in a flexible and supportive environment.

Put no limit on your engineering passion.

We would love to hear from you.

Engineers collaborating around a laptop